Solution 11815: Finding a Maximum or Minimum of a Function on a TI-89 Family, TI-92 Family, and Voyage™ 200 Graphing Calculator.
...ally have a maximum or minimum in order for it to be calculated. To find the maximum of the function -X2+X+6: 1) Press [◊] [Y=]. 2) In an open entry line, press [(-)] [X] [^] [2] [+] [X] [+] [6]. 3) Press [◊] [GRAPH]. 4) Press [F5] [4]. 5) Specify the lower bound for xc by either moving the tr...https://education.ti.com/en/customer-support/knowledge-base/other-graphing/product-usage/11815
Solution 15464: Definition of Time, Web, and Custom Settings for Axes When Graphing Sequences on the TI-89 Titanium and Voyage™ 200.
... for each sequence.• WEB: The web format produces a cobweb plot for a sequence U(n). It is better to use to display the graph as converging to an equilibrium point or veering off into space.• CUSTOM: The custom format is used to create phase plots to see how one sequence affects another sequence....https://education.ti.com/en/customer-support/knowledge-base/other-graphing/product-usage/15464
Solution 11813: Using Local Variables in Functions or Programs on the TI-89 Family, TI-92 Plus, and Voyage™ 200.
... For example, in the program segment below the variable i is a local variable: : Local i : For i,0,5,1 : Disp i : EndFor : Disp i Please Note: The line "Local i" declares i as local. When a variable is declared as local, it is deleted automatically when the program stops so that it does not us...https://education.ti.com/en/customer-support/knowledge-base/other-graphing/product-usage/11813
Solution 12093: Displaying Asymptotes on the TI-89 Family, TI-92 Plus, and Voyage™ 200 Graphing Calculators.
...e displayed on the TI-89 family, TI-92 Plus or Voyage 200? The TI-89 family, TI-92 Plus, or Voyage 200 units do not display asymptotes. The graph application plots a series of points, separated by the number of pixels specified in the "xres" variable on the window screen. As successive points ar...https://education.ti.com/en/customer-support/knowledge-base/other-graphing/product-usage/12093
Solution 11805: Negative Exponents of Zero Return Inconsistent Answers on the TI-89 Family, TI-92 Family and Voyage™ 200.
...ero. Functions of the form 1/(x-a)^(odd power), for real x and real a, have an odd-order pole at x = a. The sign changes as x crosses the pole, and limit(1/(x-a)^(odd power),x,a) = undef (the limit from the right has different sign from the limit from the left). Functions of the form 1/(x-a)^(...https://education.ti.com/en/customer-support/knowledge-base/other-graphing/product-usage/11805
Solution 11803: Viewing the Top or Bottom of a Large Matrix Result on the TI-89 Family, TI-92 Family, and Voyage™ 200 Graphing Calculators.
...ion of a large matrix that is off of the screen, follow the steps provided below. • Press the up arrow so that the visible part of the matrix is highlighted. • Press and hold the shift key (Up Arrow), which is locate to the right of the [2nd] key (For the TI-92 family and Voyage 200, the shift k...https://education.ti.com/en/customer-support/knowledge-base/other-graphing/product-usage/11803
Solution 12091: Creating a Histogram Using the TI-89 Family, TI-92 Family, and Voyage™ 200 Graphing Calculators.
...ewing window by pressing [F2] [9] for a ZoomData fit. Note: What do if I get the error message "Plot Setup" when setting up a Histogram using Stats/List Editor?The error message "Plot Setup" appears when entering a histogram with a list of large values. This is because the Stats/List Editor Pr...https://education.ti.com/en/customer-support/knowledge-base/other-graphing/product-usage/12091
Solution 11835: Decreasing the Calculation Time Needed for the nSolve() Function on the TI-89 Family, TI-92 Family, and Voyage™ 200 Graphing Calculators.
...lation time needed for the nSolve() function on the TI-89 family, TI-92 family, and Voyage 200 graphing calculators? The nSolve() function uses symbolic techniques to simplify the equation before applying the search technique. Depending on the equation, this simplification can take significant t...https://education.ti.com/en/customer-support/knowledge-base/other-graphing/product-usage/11835
Solution 11795: Using the deSolve() Function on the TI-89 Family, TI-92 Family, and Voyage™ 200 Graphing Calculators.
...-92 family, and Voyage 200. The syntax for deSolve() is: deSolve(ODE,independentvar,dependentvar) The deSolve function returns an equations that explicitly or implicitly specifies the general solution to the 1st or 2nd ordinary differential equation (ODE). Example: 1) Go to the home screen,...https://education.ti.com/en/customer-support/knowledge-base/other-graphing/product-usage/11795
Solution 14488: Rules for Variable Names on the TI-89 Titanium and Voyage™ 200.
...he same as pre-assigned names by the TI-89 Titanium or Voyage 200. Pre-assigned names include built-in functions (such as abs), instructions (such as LineVert), and system variables (such as xmin and xmax). Please see the TI-89 family and Voyage 200 guidebooks for additional information. Solut...https://education.ti.com/en/customer-support/knowledge-base/other-graphing/product-usage/14488
Solution 12088: Correcting a "Domain Error" when Performing Number Base Conversions on the TI-89 Family, TI-92 Plus and Voyage™ 200 Graphing Calculators.
...heck the mode setting:• Press [MODE].• Scroll down to the Exact/Approx setting. • Press the right arrow key.• Select EXACT or AUTO. Another possibility is that the number being entered is not a integer. The TI-89, TI-89 Titanium, TI-92 Plus, and Voyage 200 cannot convert a decimal number (ex. ...https://education.ti.com/en/customer-support/knowledge-base/other-graphing/product-usage/12088
Solution 14485: Modifying the History Area on the TI-89 Titanium and Voyage™ 200 Graphing Calculators.
...F1] and select 9:Format or press the green diamond key followed by the [|] key. 2) Press the right arrow key. 3) Use the up or down arrow keys to highlight the new number of pairs desired. • Press [ENTER] twice. 2. Clearing the history area and deleting all saved pairs: 1) From the Calc Home sc...https://education.ti.com/en/customer-support/knowledge-base/other-graphing/product-usage/14485
Solution 12087: Clock Will Not Display on a TI-89 or TI-92 Plus Graphing Calculator with Operating System (OS) 2.08 or Above.
...s a hardware version 1 unit: • On the Home Screen, with custom menus disabled, press [F1], and choose option A for About... • The About screen will list either hardware version 1 or hardware version 2. Solution 12087: Clock Will Not Display on a TI-89 or TI-92 Plus Graphing Calculator with...https://education.ti.com/en/customer-support/knowledge-base/other-graphing/product-usage/12087
Solution 12079: Creating Truth Tables Using the TI-89 Family, TI-92 Family, and Voyage™ 200.
...owledge Base Search How do I create truth tables using the TI-89 family, TI-92 family, and Voyage 200? A truth table can be created using 2 lists and the test operators on the TI-89 family, TI-92 family, and Voyage 200. To access the test operators, press [2nd] [MATH] and select 8:Test....https://education.ti.com/en/customer-support/knowledge-base/other-graphing/product-usage/12079
Solution 12048: Changing the Scale of a Graph in The Geometer's Sketchpad® App for the TI-89 Family, TI-92 Plus and Voyage™ 200 Graphing Calculators.
...e 200 graphing calculators? In order to change the scale of a graph in The Geometer's Sketchpad® App, please follow the steps listed below. For TI-89 Family users: • Press [2nd] [F1] to access the F6 menu. Select 4: Show Grid.• Move the arrow to select point (1,0). (1,0) i...https://education.ti.com/en/customer-support/knowledge-base/other-graphing/product-usage/12048
Solution 12069: Storing a Value to a Matrix Element on the TI-89 Family, TI-92 Family, and Voyage™ 200 Graphing Calculators.
... and Voyage 200 graphing calculators? For this example use the matrix below: To enter the matrix: 1) If the Apps Desktop is on, press [APPS], highlight Data/Matrix Editor, then press the [ENTER] key. (If your Apps Desktop is turned off, press [APPS][6][3] and skip the next step). 2) Choose op...https://education.ti.com/en/customer-support/knowledge-base/other-graphing/product-usage/12069
Solution 11810: Calculating a Cubic Regression on the TI-89 Family, TI-92 Family and Voyage™ 200 Graphing Calculators.
...PHA][1]. 9) Press the down arrow, then press [C][2] (Indicates the y variables are in c2). On the TI-89 family, press [ALPHA][C][2]. 10) To graph the line, select an equation number after Store RegEQ to... 11) Press [ENTER][ENTER]. A dialog box will display the cubic regression variables. ...https://education.ti.com/en/customer-support/knowledge-base/other-graphing/product-usage/11810
Solution 12046: Calculating Two-Variable Statistics on the TI-89 Family, TI-92 Family, and Voyage™ 200 Graphing Calculators.
... enter [Alpha] [c] [2]. (Indicates the y variables are in C2) The screen will appear as follows: 11) Press [ENTER] [ENTER]. A dialog box with a list of the results should appear: Please see the TI-89 family, TI-92 family and Voyage 200 guidebooks for additional information. Solution 120...https://education.ti.com/en/customer-support/knowledge-base/other-graphing/product-usage/12046
Solution 12045: Calculating the Numeric Derivative (nDeriv) on the TI-89 Family, TI-92 Family, and Voyage™ 200 Graphing Calculators.
...d(2x^3,x)|x=2 (The d( ) function is accessed by pressing [2nd] [8].) Both functions will return 24. If the value of x is not specified, the symbolic derivative will be displayed. Please see the TI-89 family, TI-92 family and Voyage 200 guidebooks for additional information. Solution 12045...https://education.ti.com/en/customer-support/knowledge-base/other-graphing/product-usage/12045
Solution 12043: Archiving a Program on the TI-89 Family, TI-92 Plus, and Voyage™ 200 Graphing Calculators.
...I-89 family, TI-92 Plus, and Voyage 200 graphing calculators? Use the following procedure to archive a program from the home screen or within the VAR-LINK menu on the TI-89 family, TI-92 Plus, and Voyage 200. Archiving from the Home Screen: • On the Home Screen, press [CATALOG] ([2nd] [CATALO...https://education.ti.com/en/customer-support/knowledge-base/other-graphing/product-usage/12043
Solution 11769: Graphing Coordinates Using the TI-89 Titanium and Voyage™ 200 Graphing Calculators.
...using the TI-89 Titanium and Voyage 200 graphing calculators? To graph coordinates using the TI-89 Titanium and Voyage 200, please follow the example listed below:The coordinates are: (2,5), (3,6), (4,7).1) Press the [APPS] key. Using the arrow keys, highlight Data/Matrix Editor icon and press [E...https://education.ti.com/en/customer-support/knowledge-base/other-graphing/product-usage/11769
Solution 11764: Graphing a Function and the Slope Field Based on that Function using a TI-89 Titanium, TI-92 Plus or Voyage™ 200 Graphing Calculators.
...ot graph a function and differential equation on the same screen at the same time. However, it is possible to graph both at the same time using the split screen function of the TI-89 Titanium, TI- 92 Plus and the Voyage 200 graphing calculators. To do this follow the steps listed below: • Press ...https://education.ti.com/en/customer-support/knowledge-base/other-graphing/product-usage/11764
Solution 11756: Finding the Sum, Difference, and Product of Two or More Matrices on the TI-89 Family, TI-92 Family, and Voyage™ 200 Graphing Calculators.
...ss [ALPHA] [A] [x] [ALPHA] [B] 2) Press [ENTER] to display the answer For additional instructions on performing matrix operations, refer to the online guidebook for your calculator. Solution 11756: Finding the Sum, Difference, and Product of Two or More Matrices on the TI-89 Family, TI-92 Fa...https://education.ti.com/en/customer-support/knowledge-base/other-graphing/product-usage/11756
Solution 12130: Difference Between the FIX and FLOAT Display Digits Mode Settings on the TI-89 Family, TI-92 Family and Voyage™ 200 Graphing Calculators.
...scientific notation if its magnitude cannot be displayed in the selected number of digits.For additional information on mode settings, refer to the online guidebook for your specific calculator model. Solution 12130: Difference Between the FIX and FLOAT Display Digits Mode Settings on the TI-89 ...https://education.ti.com/en/customer-support/knowledge-base/other-graphing/product-usage/12130
Solution 12128: Determining the Algorithm for Calculating the Average Rate of Change on the TI-89 Titanium and Voyage™ 200 Graphing Calculators.
...ge algorithm on the TI-89 Titanium and Voyage 200? The algorithm used to calculate the Average Rate of Change on the TI-89 Titanium and Voyage 200 is listed below:• avgRC(f(x),x,h) => (f(x+h)-f(x))/hThe formula being used is listed below:f(x + h) - f(x) hPlease see the TI-89 Titanium and ...https://education.ti.com/en/customer-support/knowledge-base/other-graphing/product-usage/12128