Education Technology
< Previous | 5075 - 5100 of 9859 results |  Next >

Solution 36435: Troubleshooting Quick Poll Images Not Displaying On TI-Nspire™ With Touchpad or TI-Nspire™ With Clickpad

... a badly fragmented memory. Since TI-Nspire with Touchpad and TI-Nspire with Clickpad have lower memory, they are much more likely to encounter this issue than TI-Nspire CX Handhelds. To resolve this issue, please follow these steps: Reboot your handhelds periodically to reduce memory fragmentati...
https://education.ti.com/en/customer-support/knowledge-base/ti-nspire-family/troubleshooting-messages-unexpected-results/36435

Solution 31611: Calculating Inverse Natural Logarithms Using the TI-Nspire™ Family Line of Products.

... the inverse natural logarithm (or e) of a number using the TI-Nspire family line of products. Example: Compute the inverse natural log of .5. 1) Press [home]. 2) Press [A] or choose to add a calculator. 3) Press [ex] to input the inverse natural log function (e). 4) Press [.] [5] [enter] to co...
https://education.ti.com/en/customer-support/knowledge-base/sofware-apps/computer-software-installation-activation/31611

Solution 25770: Using the Measurement Transfer Tool on the TI-Nspire™ Family Handheld and Computer Software.

...fer tool on the TI-Nspire family products, please follow the examples below. To transfer the length of segment ab to a circle using a handheld: 1) Press [home] and select [Geometry]. 2) Press [menu] [4] [5]. 3) Move to a desired location for the starting point for the segment. 4) Press [enter]...
https://education.ti.com/en/customer-support/knowledge-base/ti-nspire-family/product-usage/25770

Solution 25930: Linking Coordinate Values to Variables Using the TI-Nspire™ Family.

...riables using TI-Nspire Family products? To link coordinate values to variables using the TI-Nspire family products, follow the example below. 1) Press [home] [B] or choose to add a Graphs App. This will be the second option from the icons listed at the bottom. 2) Press [X] [-] [1] [enter]. 3)...
https://education.ti.com/en/customer-support/knowledge-base/ti-nspire-family/product-usage/25930

Solution 40371: Texas Instruments Software Displays Dialog System Extension Blocked During Install.

... with the TI-Innovator Hub. To allow this extension follow the steps below:  1) On the dialog click [Open Security Preferences]. Or if you have dismissed the dialog click [Apple] [System Preferences] [Security and Privacy] 2) Click the [Lock] icon, enter your password, and then click [Unlock] to...
https://education.ti.com/en/customer-support/knowledge-base/sofware-apps/computer-software-installation-activation/40371

Solution 37875: Steps to install TI-Connect CE on Mac OSX.

...r] then click [Go] then [Applications]. • Move the "TI-Connect CE DMG" window so it is visible at the same time as the "Applications" window then press and hold the [Mouse Click] while over the "TI-Connect CE APP". Next move the "TI-Connect CE App" over a white area of the "Applications" window ...
https://education.ti.com/en/customer-support/knowledge-base/sofware-apps/computer-software-installation-activation/37875

Solution 37679: TI-Innovator™ Hub COLOR command executes incorrectly when sound is active.

Solution 37679: TI-Innovator™ Hub COLOR command executes incorrectly when sound is active. Solution 37679: TI-Innovator™ Hub COLOR command executes incorrectly when sound is active. global Solution 37679: TI-Innovator™ Hub COLOR command executes incorrectly when sound is active. website ...
https://education.ti.com/en/customer-support/knowledge-base/ti-innovator-technology/troubleshooting-messages-unexpected-results/37679

Solution 11550: Using the Turbidity Sensor with the CBL™, CBL 2™, or Vernier LabPro® Data Collection Devices.

...r: 1. When using the Vernier LabPro® or CBL 2. • Connect the calculator to the Vernier LabPro® or CBL 2 • Put the calculator in RECEIVE mode by pressing [2nd][LINK][ENTER]. • Press the TRANSFER button on the Vernier LabPro® or CBL 2. The transfer should begin and the Datamate™ application sent...
https://education.ti.com/en/customer-support/knowledge-base/data-collection-accessories/product-usage/11550

Solution 12144: Locating the Variable List/VARS Key on the TI-89 Family, TI-92 Family, and Voyage™ 200 Graphing Calculators.

...ble needed can be manually typed using the alpha-numeric keys. For instance, if on the TI-83 family or TI-84 Plus family the instructions state to press the VARS key and select Y1, y1(x) can simply be typed using the alpha-numeric keys on the TI-89 family, TI-92 family, or Voyage 200. Please see ...
https://education.ti.com/en/customer-support/knowledge-base/other-graphing/product-usage/12144

Solution 12143: List of Predefined Constants on the TI-89 Family, TI-92 Family and Voyage™ 200 Graphing Calculators.

... _k Boltzmann's constant 1.380658E-23_J/_oK _Me Electron rest mass 9.1093897E-31_kg _Mn Neutron rest mass 1.6749286E-27_kg ...
https://education.ti.com/en/customer-support/knowledge-base/other-graphing/product-usage/12143

Solution 13302: Collecting Motion Data Using The CBR™ (Calculator Based Ranger).

...ng the Data:1. Set up the CBR on a table or other flat surface and connect it to the calculator. 2. Turn the calculator on and clear all lists by pressing [2ND] [MEM] and selecting 4: ClrAllists. Press [ENTER] and then check the lists. 3. Press [APPS] and choose CBL/CBR. Press [ENTER] and select...
https://education.ti.com/en/customer-support/knowledge-base/data-collection-accessories/product-usage/13302

Solution 10653: Proper Disposal of Used Nickel-Cadmium Batteries.

...rded? In the USA, the used Ni-Cad batteries can be dropped off at the RBRC (Rechargeable Battery Recycling Corporation) collection box at any business displaying the RBRC logo. Small commercial waste generators can send batteries for recycling under another RBRC program. See the RBRC website...
https://education.ti.com/en/customer-support/knowledge-base/data-collection-accessories/general-information/10653

Solution 11567: Automatic Start of the Vernier EasyData™ Calculator Software Application (App) for the CBR 2™.

...Connecting the cable to the calculator first will not allow the Vernier EasyData app to start automatically and the application must be started by pressing the [APPS] key. Please see the Vernier EasyData app guidebook for additional information. Solution 11567: Automatic Start of the Vernier Ea...
https://education.ti.com/en/customer-support/knowledge-base/data-collection-accessories/general-information/11567

Solution 28610: Troubleshooting the Error "The System Cannot Find the Drive Specified" When Installing TI-Nspire™ Family Version 3.0 Software From a CD

...ily Software from a CD? In some cases, the installation instructions on the CD sleeve for version 3.0 of the TI-Nspire Family of Software do not address the installation process for the correct version of the TI-Nspire Family of Software that you wish to install. The installation instructions on ...
https://education.ti.com/en/customer-support/knowledge-base/sofware-apps/computer-software-installation-activation/28610

Solution 29190: Creating a Vertical Line to Represent an Asymptote on the TI-Nspire™ Family Line of Products.

... the steps below to draw a dashed line representing an asymptote. Example: f1(X) = ((X-4) x (X+3)) / ((X-4) x (X+5)) has an asymptote at X=-5. 1) Press [home] [B]. Alternatively, click on "Add Graphs". 2) Press [(] [(] [X] [-] [4] [)] [x]. 3) Press [(] [X] [+] [3] [)] [)] [/]. 4) Press [(] [(] ...
https://education.ti.com/en/customer-support/knowledge-base/ti-nspire-family/product-usage/29190

Solution 29150: Performing Z-Test Computations on the TI-Nspire™ Family Line.

...using any of the TI-Nspire family line of products given a list of data points.   Data for this example: {299.9, 197.7, 301, 298.9, 300.2, 297} 1) Press [home] and click on "Add Lists & Spreadsheets". 2) Press [▲] [▲] [L] [1] [▼] [▼].  3) Press [2] [9] [9] [.] [9] [▼]. 4) Press [1] [9] [7] [.] [...
https://education.ti.com/en/customer-support/knowledge-base/ti-nspire-family/product-usage/29150

Solution 29170: Performing Base Conversions on the TI-Nspire™ Family Products.

...s on the TI-Nspire family products. Please Note: All calculations must be in Auto Mode. Follow steps below to put the TI-Nspire in Auto mode. 1) Press [home]. 2) Press 5: Settings. 3) Press 2: Document Settings. 4) Scroll/Tab to Calculation Mode and select 'Auto'. 5) Scroll/Tab to Make Defau...
https://education.ti.com/en/customer-support/knowledge-base/ti-nspire-family/product-usage/29170

Solution 37821: How do I turn the TI-Innovator™ Hub off?

...off? To turn the TI-Innovator Hub™ off, simply turn off the connected calculator or computer. – OR – Disconnect the USB cable If you require further assistance please contact TI-Cares for support at 1-800-TI-CARES (1-800-842-2737) or send us an E-Mail. For more details about the TI-Innovator Hub™...
https://education.ti.com/en/customer-support/knowledge-base/ti-innovator-technology/product-usage/37821

Solution 40347: Tip Sheet for Implementation of Texas Instruments Account Based Licenses.

...subscription to start. When the order is set up in our system, the start date cannot be in the past. - License Administrator: The name and email address for the license administrator who will manage the licenses and assign students. Once you make your purchase  When the Instructional Products Dea...
https://education.ti.com/en/customer-support/knowledge-base/sofware-apps/computer-software-installation-activation/40347

Solution 25130: Using the Define Command to Store a Function on the TI-Nspire™ Family Products.

... FunctionVariable(var1,var2,var3......)=Function For example, to create a function to calculate the volume of a sphere, follow the steps below: 1) Press [home] [1] to create a new document. If prompted to save the existing document, choose "Yes" or "No". Press [1] to insert the Calculator applica...
https://education.ti.com/en/customer-support/knowledge-base/ti-nspire-family/product-usage/25130

Solution 25330: Graphing a Histogram (Bar Graph) Using the TI-Nspire™ Family Products.

...ith a frequency list on the TI-Nspire family products: Data used for this example: xStat: {2, 4, 6, 8} frequency: {7, 8, 4, 9} Enter the data: • Press [home] and click on Lists & Spreadsheets. • Press [↑] [↑] [L] [1] [tab] [L] [2] [enter] to name Column A L1 and Column B L2. • Press [←] [↓] to ...
https://education.ti.com/en/customer-support/knowledge-base/ti-nspire-family/product-usage/25330

Solution 25131: Exiting out of a Graph Table using the TI-Nspire™ Family Products.

...roducts. EX: After graphing the function y=3x^2 +2, insert a function table and remove it when no longer needed. • Insert a Graphs application by pressing [home] and choosing Graphs application. • Press [3] [x] [x²] [+] [2]. • Press [enter] to see the graph. • Press [ctrl] [T] to get the table. ...
https://education.ti.com/en/customer-support/knowledge-base/ti-nspire-family/product-usage/25131

Solution 37685: TI-Innovator™ Hub first read of the temperature probe can result in 0 Kelvin (-273 C).

... Knowledge Base Knowledge Base Search Why is the first read of the temperature probe 0 Kelvin (-273 C)? Please Note: This issue is fixed in version 1.1 of Sketch please update your TI-Innovator hub to resolve this issue. If you are unable to update please read the issue...
https://education.ti.com/en/customer-support/knowledge-base/ti-innovator-technology/troubleshooting-messages-unexpected-results/37685

Solution 37688: TI-Innovator™ Hub Consecutive READ statements overload return buffer.

...LOR.RED 20\nREAD COLOR.RED",red2 The 2nd variable “red2” has information corresponding to the second READ, and not the last READ. To workaround this issue use only one READ command in each SEND command. Solution 37688: TI-Innovator™ Hub Consecutive READ statements overload return buffer. ...
https://education.ti.com/en/customer-support/knowledge-base/ti-innovator-technology/troubleshooting-messages-unexpected-results/37688

Solution 19191: Graphing Calculators Care, Cleaning and Storing a TI Graphing Calculator.

...lator's screen, keypad, or back.  Do not attempt to clean the inside of any ports.  Never use solvents or other cleaning liquids. • Avoid applying pressure to the screen/display. • Keep foreign objects from penetrating the connectivity ports on the calculator. • Keep liquids from getting inside t...
https://education.ti.com/en/customer-support/knowledge-base/ti-83-84-plus-family/product-usage/19191