Solution 13903: Calculating a Binomial Distribution on the TI-89 Family, TI-92 Plus and Voyage™ 200 Using the Statistics with List Editor Application.
...t bat Problem 1: What is the probability of getting exactly three hits? Problem 2: What is the probability of getting at least two hits? Solution 1: Computing the probability of getting exactly three hits. • From the inside the Stats/List Editor App (Application), press [F5] to select Distr • ...https://education.ti.com/en/customer-support/knowledge-base/other-graphing/product-usage/13903
Solution 13902: Algorithm for the Convert Logbase (>logbase) Function on the TI-89 Titanium and Voyage™ 200 with OS v3.10.
...Search What is the purpose of the convert logbase (>logbase)function on the TI-89 Titanium and Voyage 200 with OS v3.10? The ►logbase(n) instruction implements the following identity: loga(b) = logn(b)/logn(a) Thus, log(8) ►logbase(2) will return log2(8)/log2(10), which simplifies to 3/l...https://education.ti.com/en/customer-support/knowledge-base/other-graphing/product-usage/13902
Solution 13882: Calculating Logs With Different Bases on the TI-89 Titanium and Voyage™ 200 with OS v3.10.
...s to other bases on my TI-89 Titanium or Voyage 200 with OS v3.10 installed? OS v3.10 increases the ability of the TI-89 Titanium and Voyage 200 CAS (Computer Algebra System) to use the built in log feature for calculating log of bases other than 10. Please refer to the examples provided below. E...https://education.ti.com/en/customer-support/knowledge-base/other-graphing/product-usage/13882
Solution 32851: Boolean Logic Operation on the TI-36X Pro.
...peration in hexadecimal, octal, decimal, and binary modes. The results are displayed in the current number base. These values (except for NOT and 2's complement) compare the corresponding bits of two values. To access Boolean Logic you press [2nd] [base n ] and press the [►] twice to displays the...https://education.ti.com/en/customer-support/knowledge-base/scientific-elem-calculators/product-usage/32851
Solution 12327: Calculating Inverse Logarithms on the TI-30Xa Family and TI-36X Solar Scientific Calculators.
...Inverse logs can be calculated on TI-30Xa family and the TI-36X Solar by inputting the number, followed by the 10x function. Please see the below instructions: Example: Calculate the inverse log of .5. 1) Enter .5 and press [2nd] [LOG] (10x is labeled above it). The answer is 3.16227766. Pleas...https://education.ti.com/en/customer-support/knowledge-base/scientific-elem-calculators/product-usage/12327
Solution 12328: Calculating Logarithms Using the TI-30Xa Family or TI-34.
... Base Search How do I calculate logarithms using a TI-30Xa, TI-30Xa Solar, TI-30Xa SE, or TI-34? The examples below will demonstrate how to compute logarithms (BASE 10) on the TI-30Xa, TI-30Xa SE, or TI-34. Examples:To find the log of 100:1) Press [1] [0] [0] [LOG].The calculator will d...https://education.ti.com/en/customer-support/knowledge-base/scientific-elem-calculators/product-usage/12328
Solution 13820: Differences Between OS v3.10 and Previous Operating Systems When Solving Inequalities Using the TI-89 Titanium and Voyage™ 200.
...solving inequalities using the TI-89 Titanium or Voyage 200? OS v3.10 for the TI-89 Titanium and Voyage 200 increases the ability of the calculator's Computer Algebra System (CAS) to display more accurate results for inequalities involving polynomials and rational expressions. The table below dis...https://education.ti.com/en/customer-support/knowledge-base/other-graphing/general-information/13820
Solution 12112: Battery Life of Voyage™ 200 Graphing Calculator.
... Knowledge Base Search How long do the AAA batteries last in the Voyage 200? Voyage 200 battery life will vary based on the types of computations performed and programs that are being used. Typically the battery life will last well beyond a school year. The Voyage 200 uses four A...https://education.ti.com/en/customer-support/knowledge-base/other-graphing/general-information/12112
Solution 11844: Resetting the TI-89 Family, TI-92 Family and Voyage™ 200 Graphing Calculators.
...m Archive. This will not delete any Variables from RAM. • All Memory - Clears everything from RAM and Archive, leaving only the Calculator OS and its components. For example, if the user would like to reset All RAM, press [2nd] [6] [F1] [1] [1] [ENTER] [ENTER]. Please see the TI-89 Family, TI-92 ...https://education.ti.com/en/customer-support/knowledge-base/other-graphing/general-information/11844
Solution 11404: Unexpected Loss of Apps on the TI-89 Family, TI-92 Plus, or Voyage™ 200 Graphing Calculators.
...e is a progress bar either in the status line or in the middle of the screen at start up, the Apps are being moved in memory. If this process is interrupted, for instance by power loss or by dropping the calculator, all of the Apps that have not been successfully moved or re-installed can be lost...https://education.ti.com/en/customer-support/knowledge-base/other-graphing/general-information/11404
Solution 15809: Calculating Equivalent Units of Time on the TI-15 Explorer™.
...ge Base Knowledge Base Search How do I calculate equivalent units of time on the TI-15 Explorer™? Please see the below instructions for calculating equivalent units of time on the TI-15 Explorer. Example: A runner ran 2 kilometers in 450 seconds. Convert the runner’s ...https://education.ti.com/en/customer-support/knowledge-base/scientific-elem-calculators/product-usage/15809
Solution 11380: Engineering Applications for the TI-89 Family and Voyage™ 200 Graphing Calculators.
...eering-related Calculator Software Applications (Apps) for the Voyage 200, TI-89, and TI-89 Titanium graphing calculators: ME*Pro® App Helps solve a comprehensive set of equations used by mechanical engineering students and professionals. With a power browser engine and unit manager, it handles ...https://education.ti.com/en/customer-support/knowledge-base/other-graphing/general-information/11380
Solution 10607: Varying Processing Speeds of Some TI-89 Models.
... an increased processing efficiency for the TI-89. There is nothing wrong with the processor of slower models. The difference is analogous to newer computers that operate faster because of hardware revisions, component or software improvements. Solution 10607: Varying Processing Speeds of Som...https://education.ti.com/en/customer-support/knowledge-base/other-graphing/general-information/10607
Solution 12325: Troubleshooting a Two-line Display Scientific Calculator that Will Not Turn On.
...yed, press the [ON] key to turn the scientific calculator on. If the calculator still does not power on, please see Warranty Information on Texas Instruments Products Purchased in the United States and contact TI-Cares to obtain service information. Solution 12325: Troubleshooting a Two-line Dis...https://education.ti.com/en/customer-support/knowledge-base/scientific-elem-calculators/troubleshooting-messages-unexpected-results/12325
Solution 12264: Error Displayed When Performing Long Calculations Using the TI-30Xa Scientific Calculator.
...ple below)Example: 11757 + 3 * (500 + 7 * (138 + 257)) The calculation has been broken down to display the number of operations it will take to solve completely: 1) Pending calculation #1: 11757+3 2) Pending calculation #2: 3*(500 3) Pending calculation #3: 500+74) Pending calculation #4: 7*(138...https://education.ti.com/en/customer-support/knowledge-base/scientific-elem-calculators/troubleshooting-messages-unexpected-results/12264
Solution 15929: Range of Binary, Octal, and Hexadecimal Numbers that can be Entered on the TI-36X Solar.
...: Positive binary numbers as large as 111111111 (9 digits) can be entered on the TI-36X Solar. Numbers beyond this are interpreted as negative (two's complement) numbers. • Octal Numbers: Positive octal numbers as large as 3777777777 can be entered. Numbers beyond this are interpreted as negative...https://education.ti.com/en/customer-support/knowledge-base/scientific-elem-calculators/product-usage/15929
Solution 15420: Correcting the Error "Equation Length" on the TI-30X IIS/B and TI-30XS/TI-30XB MultiView™ Scientific Calculators.
...e maximum number of digits to enter in the entry line is 80 digits• For both model calculators, the maximum number of statistics entries is 47. NOTE: Combining an entry with a constant may make the entry exceed the limit. Please see the TI-30X IIS/B and TI-30XS/TI-30XB MultiView guidebooks for ad...https://education.ti.com/en/customer-support/knowledge-base/scientific-elem-calculators/troubleshooting-messages-unexpected-results/15420
Solution 15889: Correcting the Message "ERROR" on the TI-36X Solar.
...d by zero. • The result is larger than 9.999999999 * 10^99. • More than 15 open parentheses are used. • More than 4 pending operations are entered. • Computing the log, ln, or 1/x of zero. • Computing the log or ln of a negative number. • Computing the even root of a negative number. • Zero to th...https://education.ti.com/en/customer-support/knowledge-base/scientific-elem-calculators/troubleshooting-messages-unexpected-results/15889
Solution 17309: Calculating the Natural Log of a Value Using the TI-34 II Explorer Plus™.
... of a value using the TI-34 II Explorer Plus? To calculate the natural log (ln) of a value using the TI-34 II Explorer Plus, please see the below instructions:For Example: Calculate the natural log of 2 or ln(2).1) Press [2nd] [LOG].2) The log menu will appear, scroll to the right twice.3) Press ...https://education.ti.com/en/customer-support/knowledge-base/scientific-elem-calculators/product-usage/17309
Solution 13482: The xRes Setting is Grayed Out and Cannot be Changed on TI-89 Titanium or Voyage™ 200 with OS Version 3.10.
...ss [Enter] to confirm the selection, and then [Enter] again to save the setting.The xRes setting should now be able to be modified.For additional instructions, refer to the online guidebook for your calculator. Solution 13482: The xRes Setting is Grayed Out and Cannot be Changed on TI-89 Titan...https://education.ti.com/en/customer-support/knowledge-base/other-graphing/troubleshooting-messages-unexpected-results/13482
Solution 10180: Availability of Basic Calculator Guidebooks and Manuals.
Solution 10180: Availability of Basic Calculator Guidebooks and Manuals. Solution 10180: Availability of Basic Calculator Guidebooks and Manuals. global Solution 10180: Availability of Basic Calculator Guidebooks and Manuals. website ...https://education.ti.com/en/customer-support/knowledge-base/scientific-elem-calculators/general-information/10180
Solution 12127: Correcting a Domain Error when Calculating a Binomial CDF Using the Statistics with List Editor App on the TI-89 Family, TI-92 Plus, or Voyage™ 200 Graphing Calculators.
...ith List Editor give a Domain Error when calculating a Binomial CDF on the TI-89 family, TI-92 Plus, or Voyage 200 graphing calculators? Binomial CDF computes a cumulative probability for the discrete binomial distribution with the specified Number of Trials (n) and Probability of Success (p) on ...https://education.ti.com/en/customer-support/knowledge-base/other-graphing/troubleshooting-messages-unexpected-results/12127
Solution 25490: What is the Ohio Gradualtion Test (OGT) Red Calculator and why is it referred to as the TI-30XIISR?
... TI-30XIISR? Solution 25490: What is the Ohio Gradualtion Test (OGT) Red Calculator and why is it referred to as the TI-30XIISR? Texas Instruments has produced a red TI-30X IIS specifically for the state of Ohio to use for their Ohio Graduation Tests (OGT). These schools refer to it a...https://education.ti.com/en/customer-support/knowledge-base/scientific-elem-calculators/general-information/25490
Solution 12071: Troubleshooting a TI-89 Family, TI-92 Plus, or Voyage 200™ that Only Display Results in Fractional Format.
...mily, TI-92 Plus and Voyage™ 200. Please also see the TI-89 family, TI-92 family and Voyage 200 guidebooks for additional information. {"commands":[{"click":"chrome:field:editcontrol({command:\"webedit:editlink\"})","header":"Edit link","icon":"/temp/iconcache/networkv2/16x16/link_ed...https://education.ti.com/en/customer-support/knowledge-base/other-graphing/troubleshooting-messages-unexpected-results/12071
Solution 12041: Resolving the Error "Inconsistent Units" When Performing Temperature Conversions Using the TI-89 Family, TI-92 Family, and Voyage™ 200.
...d when standard conversion notation is used on the TI-89 family, TI-92 family, and Voyage 200. To perform temperature conversions, use the tmpCnv( ) command. The example below will demonstrate how to input a temperature conversion. Example: Convert 100 degrees Celsius to Fahrenheit. To Solve:...https://education.ti.com/en/customer-support/knowledge-base/other-graphing/troubleshooting-messages-unexpected-results/12041