Solution 12264: Error Displayed When Performing Long Calculations Using the TI-30Xa Scientific Calculator.
...ulations? The TI-30Xa uses a AOS (Algebraic Operating System) which means it stores up to 4 pending operations in memory (2 when STAT is displayed). Equations with 5 or more pending operations violate this limitation causing the calculator to display an error. (see the example below)Example: 1175...https://education.ti.com/en/customer-support/knowledge-base/scientific-elem-calculators/troubleshooting-messages-unexpected-results/12264
Solution 15929: Range of Binary, Octal, and Hexadecimal Numbers that can be Entered on the TI-36X Solar.
... from FDABF41C01 through FFFFFFFFF are interpreted as negative numbers (two's complements). Hexadecimal numbers between 2540BE3FF and FDABF41C01 are equivalent to decimal values that are outside the range of the calculator and cause errors. Please see the TI-36X Solar guidebook for additional inf...https://education.ti.com/en/customer-support/knowledge-base/scientific-elem-calculators/product-usage/15929
Solution 15889: Correcting the Message "ERROR" on the TI-36X Solar.
...h root of a number. • Converting from rectangular to polar when x or y has an exponent greater than 63. • Computing the tangent of 90 degrees or any equivalent angle. • Computing the inverse sine or cosine of a number which absolute value is greater than 1. • Computing permutation or combinations...https://education.ti.com/en/customer-support/knowledge-base/scientific-elem-calculators/troubleshooting-messages-unexpected-results/15889
Solution 12135: Error Invalid Polar Complex on the TI-89 Family, TI-92 Plus and Voyage™ 200.
... complex form. Refer to the tips provided below for inputting polar complex numbers. Complex numbers can be entered in two different polar forms.• reiq - Must be entered with the calculator in Radian mode. Inputting polar complex numbers while the calculator is in degree mode will trigger error m...https://education.ti.com/en/customer-support/knowledge-base/other-graphing/troubleshooting-messages-unexpected-results/12135
Solution 12127: Correcting a Domain Error when Calculating a Binomial CDF Using the Statistics with List Editor App on the TI-89 Family, TI-92 Plus, or Voyage™ 200 Graphing Calculators.
...ty of Success (p) on each trial. The Statistics with List Editor App, version 1.01, is limited to calculating a Binomial CDF with a number of trials equal to or less than 999. The latest version of Statistics with List Editor App does not have this limitation and is currently available for the TI...https://education.ti.com/en/customer-support/knowledge-base/other-graphing/troubleshooting-messages-unexpected-results/12127
Solution 11591: Correcting the Circular Definition Error on the TI-89 Family, TI-92 Family, and Voyage™ 200 Graphing Calculators.
...expected result!) To avoid this, functions and programs should be defined with argument variable names that WILL NOT be used as arguments during subsequent function or program calls. Please avoid choosing variable names like x,y,z,a,b,c,... for argument names when defining a function or program. ...https://education.ti.com/en/customer-support/knowledge-base/other-graphing/troubleshooting-messages-unexpected-results/11591
Solution 11501: Resolving Error Skipping: Keyfon73.fon When Installing the TI Connect™ Software.
...TI Connect? The error Skipping: Keyfon73.fon indicates that the TI-73 key font is not properly installed on the computer. The TI Connect software requires this font prior to installation. To correct this error, follow the steps listed below: • Click on Start, Settings, Control Panel (or Start, ...https://education.ti.com/en/customer-support/knowledge-base/other-graphing/troubleshooting-messages-unexpected-results/11501
Solution 10441: Resolving ERROR 13 DIMENSION or ERROR 12 DIM MISMATCH Message on the TI-86.
...RROR 12 DIM MISMATCH is the result of one or more stat plots being selected when not using the stat plots feature of the TI-86. The following key sequence can be used to turn the stat plots off: 1) [2nd] [STAT] 2) [F3] 3) [F5] 4) [ENTER] This will turn all plots off and should allow for n...https://education.ti.com/en/customer-support/knowledge-base/other-graphing/troubleshooting-messages-unexpected-results/10441
Solution 20469: Incorrect Answer Received When Dividing Two Values in Scientific Notation Using the TI-30XS/B MultiView™ and TI-34 MultiView™ Scientific Calculators.
... TI-30XS/B MultiView and TI-34 MultiView? The TI-30XS/B MultiView and TI-34 MultiView calculators have a specific scientific notation shortcut key unique to all other scientific calculators, [x10n]. When dividing two values in scientific notation, it is necessary to put parentheses around the se...https://education.ti.com/en/customer-support/knowledge-base/scientific-elem-calculators/product-usage/20469
Solution 12711: Availability of Overhead Versions of Non-Graphing Calculators.
Solution 12711: Availability of Overhead Versions of Non-Graphing Calculators. Solution 12711: Availability of Overhead Versions of Non-Graphing Calculators. global Solution 12711: Availability of Overhead Versions of Non-Graphing Calculators. website ...https://education.ti.com/en/customer-support/knowledge-base/scientific-elem-calculators/general-information/12711
Solution 11804: The Anti-Derivative of Sin(x)*Cos(x) Returns an Expression in Cos(x) Instead of Sin(x) on the TI-89 Family, TI-92 Plus and Voyage™ 200.
...mplified. Internally, the integrand is stored as cos(x)*sin(x). TI could have chosen to store the integrand as sin(x)*cos(x), but either ordering is equally acceptable. • Then the algorithm attempts to verify whether the integrand is of the form const*elementary_function(u(x))*u'(x). Here, the ...https://education.ti.com/en/customer-support/knowledge-base/other-graphing/troubleshooting-messages-unexpected-results/11804
Solution 12685: Batteries For A Scientific Calculator.
...ONE NO TI-68 CR2032 NONE NO *The number of batteries required for the TI-30Xa Scientific Calculator will vary 1 or 2 lithium batteries. Note: The "A76" battery replaces the "LR44" Solution 12685: Batte...https://education.ti.com/en/customer-support/knowledge-base/scientific-elem-calculators/general-information/12685
Solution 22310: Correcting the Error Message Variable is Locked, Protected, or Archived on the TI-89 Family, TI-92 Family and Voyage™ 200.
...mily and Voyage 200 graphing calculator? The error, Variable is Locked, Protected, or Archived, appears when attempting to delete a locked program, equation, list, etc. from the var-link menu using a TI-89 family, TI-92 family or Voyage 200 calculator. Since the item to be deleted is locked, th...https://education.ti.com/en/customer-support/knowledge-base/other-graphing/troubleshooting-messages-unexpected-results/22310
Solution 20889: Ranger Program Will Not Work with CBL/CBR App on TI-83 Plus Family Graphing Calculators with OS 1.19.
...phing Calculator products Knowledge Base Knowledge Base Search How can I enable the RANGER program to execute after upgrading the OS to version 1.19 on a TI-83 Plus family graphing calculator? Solution 20889: Ranger Program Will Not Work with CBL/CBR App ...https://education.ti.com/en/customer-support/knowledge-base/other-graphing/troubleshooting-messages-unexpected-results/20889
Solution 12258: Differences Between the TI-30Xa and the TI-30X IIS/B.
...I-30X IIS/B? The TI-30X IIS/B have the features of the TI-30Xa, and also includes two lines (top line is entry line and bottom line is answer line), equation recall/edit feature, two variable statistics, memory retention feature (retains previous entries, memory values, and individual statistical...https://education.ti.com/en/customer-support/knowledge-base/scientific-elem-calculators/general-information/12258
Solution 12257: Differences Between the TI-30X IIB And the TI-30X IIS.
Solution 12257: Differences Between the TI-30X IIB And the TI-30X IIS. Solution 12257: Differences Between the TI-30X IIB And the TI-30X IIS. global Solution 12257: Differences Between the TI-30X IIB And the TI-30X IIS. website ...https://education.ti.com/en/customer-support/knowledge-base/scientific-elem-calculators/general-information/12257
Solution 11845: Resolving the Error Message "Illegal Instruction" on the TI-89 Family, TI-92 Family, and Voyage™ 200 Graphing Calculators.
... does not restore the unit, remove a battery and press [ON] for 30 seconds. Replace the battery, turn on the unit, and adjust the contrast. If you require additional assistance please contact TI-Cares. Solution 11845: Resolving the Error Message "Illegal Instruction" on the TI-89 Family, TI-92 ...https://education.ti.com/en/customer-support/knowledge-base/other-graphing/troubleshooting-messages-unexpected-results/11845
Solution 12229: Differences Between the TI-10 and TI-15 Explorer™.
...ifferences were necessary to make it grade appropriate. The TI-10 has fewer and larger keys. The keys for fractions, the [0.001] thousandths key, p, square root, [^] caret, and % have been omitted from the TI-10. The unit has only one operation key as opposed to two on the TI-15 Explorer. Separa...https://education.ti.com/en/customer-support/knowledge-base/scientific-elem-calculators/general-information/12229
Solution 12256: Converting from Rectangular to Polar Coordinates Using the TI-30X IIS/B and TI-30XS MultiView™.
...ert rectangular coordinates to polar coordinates, please follow the example listed below: Convert the rectangular coordinate (4,3) to polar form (r, q). To find r or magnitude: • Press [DRG] • Using the left and right arrow keys, underline DEG (for Degree mode) • Press [ENTER] • Press [2nd] [°...https://education.ti.com/en/customer-support/knowledge-base/scientific-elem-calculators/product-usage/12256
Solution 12280: Calculating Standard Deviation on the TI-30X IIS/B, TI-30XS MultiView™ and TI-34 II Explorer Plus™.
...type the value and press [ENTER]. Press the down arrow key to move on to the next data point. Data points alternate between the x value, and the x frequency. 3) [STATVAR] displays the menu of variables with their current values. Answers should be as follows: Sx (Sample Standard Deviation) = 1 s...https://education.ti.com/en/customer-support/knowledge-base/scientific-elem-calculators/product-usage/12280
Solution 12283: Converting from Rectangular to Polar Coordinates Using the TI-34 II Explorer Plus.
...lar coordinates using the TI-34 II Explorer Plus, please follow the example listed below: Convert the rectangular coordinate (4,3) to polar form (r, q). To find r or magnitude: 1) Press [2nd][←F]. 2) Using the left and right arrow keys, underline DEG (for Degree mode). 3) Press [ENTER]. 4) Pre...https://education.ti.com/en/customer-support/knowledge-base/scientific-elem-calculators/product-usage/12283
Solution 34692: Using the Statistics Wizard on the TI-84 Plus Family of Graphing Calculators.
... statistics wizard format on the TI-84 Plus family of graphing calculators? The TI-84 Plus family of graphing calculators allows entering statistics equations, in a wizard format making entering the information more intuitive. To enable and disable the wizard format by going to [Mode] and chang...https://education.ti.com/en/customer-support/knowledge-base/ti-83-84-plus-family/product-usage/34692
Solution 34657: Converting an Angle from Radian to Degree on the TI-83 Plus and TI-84 Plus Family of Graphing Calculators.
...radian to degree, please follow the steps listed below: 1) Press [MODE] [↓] [↓] [→] [ENTER] to change the mode setting to degree. 2) Press [2nd] [Quit] [Clear] to quit out the mode screen and clear the home screen. 3) Press [2] [2nd] [π] [2nd] [ANGLE] [3] [Enter] this will convert the 2π t...https://education.ti.com/en/customer-support/knowledge-base/ti-83-84-plus-family/product-usage/34657
Solution 34619: Finding the Limit of a Function on the TI-83 Plus and TI-84 Plus Family of Graphing Calculators.
...y [graph] to display the table. 8) Looking at the numbers in the table as x approaches 3. This will give us the limit as X approaches 3, which is equal to 2. Please see the TI-83 Plus and TI-84 Plus Family guidebooks for additional information. Last updated: 7/17/2023 Solution 34619: Finding...https://education.ti.com/en/customer-support/knowledge-base/ti-83-84-plus-family/product-usage/34619
Solution 34611: Computing One Way Analysis of Variance (ANOVA) on the TI-83 Plus and TI-84 Plus Family of Graphing Calculators.
... completely randomized design is used. A robotic golfer, using a driver, is set up to hit a random sample of 24 balls (8 of each brand) in a random sequence follow the steps below: 1) Press [stat] [5] [enter] to restore default lists 2) Press [stat] [4] [2nd] [1] [,] [2nd] [2] [,] [2nd] [3] [ent...https://education.ti.com/en/customer-support/knowledge-base/ti-83-84-plus-family/product-usage/34611