Education Technology
< Previous | 700 - 725 of 11286 results |  Next >

Solution 11805: Negative Exponents of Zero Return Inconsistent Answers on the TI-89 Family, TI-92 Family and Voyage™ 200.

...nity (the limit from the right = infinity, and the limit from the left = infinity). On the TI-89 family, TI-92 family and Voyage 200 the following occurs when a zero base is raised to a negative exponent: 0^-1 solution "undef" 0^-2 solution infinity 0^-3 solution "undef" 0^-4 solution infinity...
https://education.ti.com/en/customer-support/knowledge-base/other-graphing/product-usage/11805

Solution 12085: Apps Icon Desktop Setting and Clock Functionality for the TI-89 or TI-92 Plus.

...the Voyage™ 200. Please note that the clock will only work on units whose About screens read Hardware Version 2.00. The About screen may be found by accessing the calculator's Home screen then pressing F1 Tools, and choosing A: About. For additional instructions on performing matrix operations, r...
https://education.ti.com/en/customer-support/knowledge-base/other-graphing/product-usage/12085

Solution 11869: Performing Unit Conversions On The TI-89 Family,TI-92 Family, and Voyage™ 200 Graphing Calculators.

...to another in the same category, including user-defined units. For example, to convert 4 light years to kilometers: • Enter 4 • Press [2nd][3] to access the UNITS menu (On Voyage 200 press [♦][P]) • In the Length menu, select _ltyr, • Press [2nd][MODE] to select the convert icon (on the ...
https://education.ti.com/en/customer-support/knowledge-base/other-graphing/product-usage/11869

Solution 10352: Inputting Complex Numbers on the TI-85 or TI-86 Graphing Calculators.

... complex number in polar form is to separate the magnitude and angle using the angle symbol. The syntax is: (magnitude < angle). The angle symbol is accessed by pressing [2nd] [,]. Please refer to the examples provided below:Please Note: To activate complex mode press [2nd][CPLX].(3+7i) would be ...
https://education.ti.com/en/customer-support/knowledge-base/other-graphing/product-usage/10352

Solution 10578: Degree, Minutes, Seconds (DMS) Conversions with the TI-82.

... quote after each value. For example, to convert 15 degrees, 12 minutes and 8 seconds to decimal degrees, input 15'12'8' and press [ENTER]. The ' is accessed by pressing [2nd] [ANGLE] [2]. To convert a number that is written in decimal degrees to DMS, follow the example below: Convert 12.2525 t...
https://education.ti.com/en/customer-support/knowledge-base/other-graphing/product-usage/10578

Solution 11505: Sending Files from a TI-82 or TI-85 to a Macintosh® with the TI-GRAPH LINK 2 or the TI Connect™ Software.

...ntosh® with the TI-GRAPH LINK 2 or the TI Connect software? When sending files to a Macintosh® computer from a TI-82 or a TI-85, it is necessary to access the LINK menu on the calculator, select the variables to transmit, and select TRANSMIT on the TI-82 and SEND on the TI-85. Note: The Connecti...
https://education.ti.com/en/customer-support/knowledge-base/other-graphing/product-usage/11505

Solution 10357: Unexpected Results Returned Performing Temperature Conversions with Negative Numbers on the TI-85 and TI-86.

...er and (-40)°C>°F, will return -40, the expected answer.  Please refer to the steps provided below.• Press [(] [(-)] [4] [0] [)]• Press [2nd] [5] to access the conversion menu (CONV)• Press [F5] for the TEMP menu•Press [F1] for °C (Celsius), the conversion symbol will populate behind the °C• Pres...
https://education.ti.com/en/customer-support/knowledge-base/other-graphing/product-usage/10357

Solution 11775: Inserting Comments in a TI Basic Program on the TI-89 Family, TI-92 Family, and Voyage™ 200.

...he © symbol indicates a program comment. Any information to the right of the © symbol will not be executed when the program runs.The © symbol can be access by pressing the green diamond [♦] key and then the close parenthesis [ ) ] key while editing a program, or from the CATALOG menu.Below is an ...
https://education.ti.com/en/customer-support/knowledge-base/other-graphing/product-usage/11775

Solution 18249: Finding the Real and Imaginary Parts, and Modulus (Absolute Value) of an Algebraic Expression using Complex Numbers on the TI-89 Family, TI-92 Family and Voyage™ 200 Graphing Calculators.

... highlight and select Auto and press [ENTER][ENTER]. 2) On the home screen press [2nd][MATH][5][2]. 3) Enter ((1+i)(5-2i)). The imaginary i can be accessed by pressing [2nd][Catalog] on the TI-89 family and [2nd][I] on the TI-92 Plus and Voyage 200. To find the imaginary parts, please follow...
https://education.ti.com/en/customer-support/knowledge-base/other-graphing/product-usage/18249

Solution 31951: Correcting a TI-89 Family, TI-92 Family, or Voyage™ 200 Graphing Calculator That is Locked Displaying "Busy" When Calculating Sigma Summation.

...ror that is displayed on my TI-89 family, TI-92 family, or Voyage 200 graphing calculator when I calculate sigma summation? The summation failures occur when the calculator attempts to locate an exact equivalence for a calculation that can only be displayed as a decimal approximation. To correc...
https://education.ti.com/en/customer-support/knowledge-base/other-graphing/product-usage/31951

Solution 11695: Algorithm Used to Compute a Cubic Polynomial on a TI-85, TI-86, TI-89 Family, TI-92 Family, and Voyage™ 200 Graphing Calculators.

...y use different linear system solvers, which use slightly different criteria for determining when a linear system is too poorly conditioned to solve accurately. Apparently, the linear system solver on the TI-89 family and TI-92 family (simult) is slightly more conservative than the one on the TI-...
https://education.ti.com/en/customer-support/knowledge-base/other-graphing/product-usage/11695

Solution 11837: Difference Between Complex Numbers on the TI-89 Family, TI-92 Family, or Voyage™ 200 Graphing Calculators.

...92 family, and Voyage 200? The TI-92 and the TI-89 family/TI-92 Plus/Voyage 200 differ in the way polar form complex numbers are handled. The TI-92 accepts the form r*eiq and must be in radian mode. If entering a degree value, the degree symbol must be used. The q value in the result would be a ...
https://education.ti.com/en/customer-support/knowledge-base/other-graphing/general-information/11837

Solution 11374: Compatibility Between TI-89 Family, TI-92 Family, and Voyage™ 200 Graphing Calculators Data and Programs.

...m a TI-89, TI-89 Titanium, TI-92 Plus, or Voyage 200 to a TI-92 is made, the sending calculator automatically checks to be sure the functionality is acceptable for the TI-92. If not, the data is not sent. This protects the TI-92 because tokenized data can cause the TI-92 to lock up. 4) If tokeniz...
https://education.ti.com/en/customer-support/knowledge-base/other-graphing/general-information/11374

Solution 11402: Starting the Calculus Tools Application on the TI-89 Family.

... Knowledge Base Knowledge Base Search Where is the Calculus Tools menu and why do I see a normal TI-89 family menu after accessing the App? The Calculus Tools App requires specific mode settings to run correctly. If one of these mode settings is different, the App wil...
https://education.ti.com/en/customer-support/knowledge-base/other-graphing/product-usage/11402

Solution 34293: Computing Binomialcdf on the TI-36X Pro.

...-36X Pro? Binomialcdf computes a cumulative probability at x for the discrete binomial distribution with the specified numtrials and probability of success (p) on each trial. x can be nonnegative integer and can be entered with options of SINGLE, LIST or ALL (a list of cumulative probabilities is...
https://education.ti.com/en/customer-support/knowledge-base/scientific-elem-calculators/product-usage/34293

Solution 15889: Correcting the Message "ERROR" on the TI-36X Solar.

... Why is my TI-36X Solar displaying the message "Error" and how can I correct it? When "Error" appears on the display, the calculator will not accept a keyboard entry. Press the [CE/C] to clear the error condition. Press the [CE/C] twice to clear the condition and all pending operations. Th...
https://education.ti.com/en/customer-support/knowledge-base/scientific-elem-calculators/troubleshooting-messages-unexpected-results/15889

Solution 12127: Correcting a Domain Error when Calculating a Binomial CDF Using the Statistics with List Editor App on the TI-89 Family, TI-92 Plus, or Voyage™ 200 Graphing Calculators.

...s? Binomial CDF computes a cumulative probability for the discrete binomial distribution with the specified Number of Trials (n) and Probability of Success (p) on each trial. The Statistics with List Editor App, version 1.01, is limited to calculating a Binomial CDF with a number of trials equal ...
https://education.ti.com/en/customer-support/knowledge-base/other-graphing/troubleshooting-messages-unexpected-results/12127

Solution 12089: Correcting the Error Message "Press I to Install Code" on the TI-89 Family, TI-92 Plus or Voyage™ 200 Graphing Calculators Using the TI Connect™ Software for Windows®.

...to install code, appears on the TI-89 family, TI-92 Plus and Voyage 200 when the unit has lost its operating system. In general, this situation only occurs as the result of interrupting the transfer of the operating system from a computer or another calculator once it has begun.To correct the sit...
https://education.ti.com/en/customer-support/knowledge-base/other-graphing/troubleshooting-messages-unexpected-results/12089

Solution 18729: Performing Metric Conversions on the TI-36X II.

...metric conversions on the TI-36X II? The TI-36X II has a menu with 20 conversions from the metric system into the English system and vice versa. To access this menu press [Conver] and scroll to the selected conversion and press [ENTER]. To reverse the conversion press [2nd] while the selected un...
https://education.ti.com/en/customer-support/knowledge-base/scientific-elem-calculators/product-usage/18729

Solution 11591: Correcting the Circular Definition Error on the TI-89 Family, TI-92 Family, and Voyage™ 200 Graphing Calculators.

...xpressions of symbolic variable argument names that are the same as those used to define the function or program. The error Circular definition will occur if that is detected. Unexpected results can occur when a function or program is called with some form of the same variable name that was used ...
https://education.ti.com/en/customer-support/knowledge-base/other-graphing/troubleshooting-messages-unexpected-results/11591

Solution 10419: Correcting ERROR 20 GRAPH WINDOW on the TI-86.

... Knowledge Base Knowledge Base Search How can I correct ERROR 20 GRAPH WINDOW on the TI-86? The ERROR 20 GRAPH WINDOW occurs when the minimum value for x or y is larger than the maximum value. Edit the window values to resolve this error: 1) Press [GRAPH] [F2] and i...
https://education.ti.com/en/customer-support/knowledge-base/other-graphing/troubleshooting-messages-unexpected-results/10419

Solution 11804: The Anti-Derivative of Sin(x)*Cos(x) Returns an Expression in Cos(x) Instead of Sin(x) on the TI-89 Family, TI-92 Plus and Voyage™ 200.

.... Internally, the integrand is stored as cos(x)*sin(x). TI could have chosen to store the integrand as sin(x)*cos(x), but either ordering is equally acceptable. • Then the algorithm attempts to verify whether the integrand is of the form const*elementary_function(u(x))*u'(x). Here, the first fa...
https://education.ti.com/en/customer-support/knowledge-base/other-graphing/troubleshooting-messages-unexpected-results/11804

Solution 30130: When Using Symbolic Pi, Mixed Number Conversions are Improperly Displayed on the TI-36X Pro and TI-30X Pro MultiView™ Calculators.

...the interpretation of that result, is not correct. Once you do this, any other mixed fractions that include pi calculations you attempt to do will inaccurately display. Sample problem: Area of a Circle: Not all screens are shown. • Enter a calculation with Pi • Toggle to fraction result. Th...
https://education.ti.com/en/customer-support/knowledge-base/scientific-elem-calculators/product-usage/30130

Solution 10438: Performing Polar to Rectangular and Rectangular to Polar Conversions on the TI-85 and TI-86.

...he solution. The < symbol denotes the "angle" symbol on the calculator. To convert from rectangular to polar: 1) Input (5<53.13). Please Note: To access the < (angle) symbol, press [2nd] [,]. 2) Press [2nd] [CPLX] 3) Press [MORE] [F1] [ENTER] The screen will show (3.000..., 3.999...) as the ...
https://education.ti.com/en/customer-support/knowledge-base/other-graphing/troubleshooting-messages-unexpected-results/10438

Solution 12256: Converting from Rectangular to Polar Coordinates Using the TI-30X IIS/B and TI-30XS MultiView™.

...gular coordinate (4,3) to polar form (r, q). To find r or magnitude: • Press [mode] [enter] [2nd] [mode] (for Degree mode). • Press [2nd] [prb] (to access the angle menu) and scroll over to highlight R◄►P. • Press [1] to paste R►Pr( on the screen. • Input the x-value of the rectangular coordinat...
https://education.ti.com/en/customer-support/knowledge-base/scientific-elem-calculators/product-usage/12256